    X-Ray Powder Diffactometer (XRPD)

    Bruker D8 Discovery

    Applications

    • Standard X-ray powder diffraction:
      • Qualitative and quantitative phase analysis
      • Several measurement setups available:
        • Reflection, Transmission, Debye-Scherrer (capillary)
        • Bragg-Brentano and Parallel Beam geometry
    • Structure analysis and solution
      • Monochromatic Cu- or Mo-K alpha1 radiation (Johansson monochromators) available for structure refinement and solution
    • Non-ambient measurement conditions:
      • High temperature measurements up to 1200°C
      • Measurements with defined relative humidity
    • Analysis of challenging samples:
      • Combination of zero-background sample holders, air-tight sample preparation techniques, freely movable xyz-sample stage, focusing Goebel mirror and 2D-detector allows analysis of samples that are
        • air sensitive
        • weakly scattering
        • not easy to prepare with standard sample preparation tools
        • only available in very small amounts

    Specifications

    • X-ray sources:
      • Cu ceramic tube, output 2.2 kW
      • Mo ceramic tube, output 3.0 kW
    • Primary side:
      • Johansson monochromators for monochromatic Cu- or Mo-K alpha1 radiation
      • Focusing Goebel mirror
      • Variable divergence slit or several fixed divergence slits
      • Micro slits and point collimators
    • Goniometer:
      • Usable 2 theta angle range (approx.) -100° to 330°
      • Smallest stepsize: 0.0001°
    • Sample Stages:
      • Rotation stage (standard) for transmission and reflection geometry
      • Capillary stage for Debye-Scherrer geometry
      • Motorized xyz-stage
        • x, y, z: 0 – 24 mm
        • usable with all specimen holders for reflection geometry
        • specially designed flow-through cell (partially still in development)
      • mri TC-H humidity chamber
        • Tunable relative humidity: 0 – 95%
        • Temperature rt – 90°C (with controlled humidity) or up to 300°C (dry N2 stream)
      • Anton Paar HTK 1200 high temperature chamber:
        • for temperatures up to 1200°C
        • reflection or Debye-Scherrer (capillary) geometry
      • Secondary side:
        • Motorized slit as scattering beam aperture
        • Mount for various slits and filters
      • Detectors:
        • LynxEye 0D/1D detector (usable as 0D point detector or 1D detector with 192 channels)
        • Våntec 500 2D detector

    Hinweis zum Datenschutz

    Mit 'OK' verlassen Sie die Seiten der Universität Würzburg und werden zu Facebook weitergeleitet. Informationen zu den dort erfassten Daten und deren Verarbeitung finden Sie in deren Datenschutzerklärung.

    Hinweis zum Datenschutz

    Mit 'OK' verlassen Sie die Seiten der Universität Würzburg und werden zu Twitter weitergeleitet. Informationen zu den dort erfassten Daten und deren Verarbeitung finden Sie in deren Datenschutzerklärung.

    Kontakt

    Wilhelm-Conrad-Röntgen-Forschungszentrum für komplexe Materialsysteme

    Suche Ansprechpartner

    Hubland Süd Hubland Nord